Download 2014 ASHRAE Handbook -- Refrigeration (I-P) (Ashrae Handbook by ASHRAE PDF

By ASHRAE

The 2014 ASHRAE Handbook€”Refrigeration covers the refrigeration apparatus and structures for purposes except human convenience. This quantity contains info and information on cooling, freezing, and storing foodstuff; commercial and scientific functions of refrigeration; and low-temperature refrigeration; and features a dual-unit CD.

CD procedure specifications: home windows: CD-ROM force; 1.3 GHz or swifter processor; Microsoft home windows Vista, home windows 7, or home windows eight (62-bit and 64-big); 1 GB of RAM (2 GB recommended); Microsoft net Explorer eight or better; Adobe Acrobat/Reader 10.0 or larger; 350 MB hard-disk house. Macintosh: Mac OS X v. 10.5.8 or v. 10.6.4; 512 MB of RAM (1 GB recommended); 415 MB hard-disk house; 800 x six hundred monitor solution (1024 x 768 recommended); Safari four for Mac OS X v. 10.5.8, Safari four or 5.0x for Mac OS X v. 10.6.4, Safari 6.0 for Mac OS X v. 10.7.4 or v. 10.8; Firefox; Adobe Acrobat/Reader 10.0 or larger. quotation: 2014 ASHRAE Handbook

ASHRAE, based in 1894, is a global association of a few 50,000 folks. ASHRAE fulfills its project of advancing heating, air flow, air con, and refrigeration to serve humanity and advertise a sustainable global via study, criteria writing, publishing, and carrying on with schooling.

The ASHRAE Handbooks are the layout general for regulate of outfitted environments with volumes on platforms and kit, HVAC purposes, Refrigeration and basics. every one is up-to-date each 4 years. as well as publishing layout suggestions for engineers, architects, and facility managers, we additionally put up a chain of texts for school room use.

a number of the parts we post in include:
-Energy Modeling and Auditing
-High functionality construction Design
-Psychrometrics
-Indoor Air caliber and Environmental Quality
-Data heart power Efficiency
-Noise & Vibration Control
-Humidity Control
-HVAC for Healthcare amenities

Show description

Read Online or Download 2014 ASHRAE Handbook -- Refrigeration (I-P) (Ashrae Handbook Refrigeration Systems/Applications Inch-Pound System PDF

Best ventilation & air conditioning books

Damage and fracture mechanics : failure analysis of engineering materials and structures

The 1st African InterQuadrennial ICF convention “AIQ-ICF2008” on harm and Fracture Mechanics – Failure research of Engineering fabrics and Structures”, Algiers, Algeria, June 1–5, 2008 is the 1st within the sequence of InterQuadrennial meetings on Fracture to be held within the continent of Africa. in the course of the convention, African researchers have proven that they advantage a robust recognition in foreign circles and proceed to make monstrous contributions to the sector of fracture mechanics.

Extra resources for 2014 ASHRAE Handbook -- Refrigeration (I-P) (Ashrae Handbook Refrigeration Systems/Applications Inch-Pound System

Example text

In direct-expansion systems using coils or tube bundles that require bottom feed for good liquid distribution and where refrigerant carryover from the top of the evaporator is essential for proper oil removal. • In low-temperature systems, where it is advantageous to have as little oil as possible going through the low side. • In screw-type compressor systems, where an oil separator is necessary for proper operation. The oil separator is usually supplied with the compressor unit assembly directly from the compressor manufacturer.

However, because most microchannel condensers are made up of many individual heat exchangers, there is an opportunity to mechanically isolate portions of the condenser to reduce the usable surface area. This type of control scheme can be used instead of holding back excess refrigerant to flood portions of the condenser. KEEPING LIQUID FROM CRANKCASE DURING OFF CYCLES Control of reciprocating compressors should prevent excessive accumulation of liquid refrigerant in the crankcase during off cycles.

Double Hot-Gas Risers. A double hot-gas riser can be used the same way it is used in a suction line. Figure 18 shows the double riser principle applied to a hot-gas line. Its operating principle and sizing technique are described in the section on Double Suction Risers. Single Riser and Oil Separator. As an alternative, an oil separator in the discharge line just before the riser allows sizing the riser for a low pressure drop. Any oil draining back down the riser accumulates in the oil separator.

Download PDF sample

Rated 4.58 of 5 – based on 44 votes